- Mission Critical Projects
Telecommunication Services
Fortune 200 Telecom Data Centers
Telecommunications Data Center – 7,500 K;, 60,000 SQFT
Lewis Center, Ohio
Project managed and designed “N+N’ power distribution system for 60,000
square foot Data Center for Telecommunications Company. Project construction
period is approximately 7 months from conceptual design to final occupancy.
Standby Power generation: 7,500 KW
UPS Power: 4000 KVA
Telecommunications Data Center (V3) – 6,000 KW; 20,000 SQFT
Sterling, VA
Project managed and designed “N+N’ power distribution system for 20,000 square
foot Data Center for Telecommunications Company. Project construction period
is approximately 12 months from conceptual design to final occupancy.
Standby Power generation: 6,000 KW
UPS Power: 4000 KVA
Telecommunications Data Center – 6,000 KW
Sacramento, CA
Designed and managed the expansion of UPS distribution system, and
air distribution systems.
Standby Power Generation: 6000 KW
UPS Power: 3000 KVA
Telecommunications Data Center – 12,000 KW
Denver1, CO
Designed and managed the expansion of UPS distribution system, and
air distribution systems.
Standby Power Generation: 12000 KW
UPS Power: 4000 KVA
Telecommunications Data Center
Sunnyvale, CA
Designed and managed the installation of new UPS system,
4000 amp service entrances, 12 KV utility distribution,
standby generator plant, chilled water plant and air
distribution systems.
Standby Power Generation: 6250 KW
UPS Power: 6000 KVA
Telecommunications Data Center – 6,250 KW
Burbank, CA
Designed and managed the installation of new UPS system, 4000 amp
service entrances, 12 KV utility distribution, standby generator
plant, condenser water plant and air distribution systems.
Standby Power Generation: 6250 KW
UPS Power: 4000 KVA
Telecommunications Data Center – 4,000 KW; 17,000 SQFT
Sunnyvale 2, CA
Commissioned the critical systems for a 17,000 square foot data center.
System includes an N+N utility distribution, standby generators and UPS systems.
Cooling system consisted of Glycol CRAC units and dry coolers located on the roof.
Standby Power Generation: 4000 KW
UPS Power: 3000 KVA
Telecommunications Data Center – 8,000 KW
Denver3, CO
Designed and managed the expansion of UPS distribution system, and
air distribution systems.
Standby Power Generation: 8000 KW
UPS Power: 6000 KVA
Telecommunications Data Center – 8,750 KW
Seattle, WA
Designed and managed the expansion of UPS distribution system, and
air distribution systems.
Standby Power Generation: 8750 KW
UPS Power: 6000 KVA
Telecommunications Data Center – 8,750 KW
Seattle, WA
Designed and managed the expansion of UPS distribution system, and
air distribution systems.
Standby Power Generation: 8750 KW
UPS Power: 6000 KVA
Telecommunications Data Center – 12,000 KW
Chicago, IL
Designed and managed the expansion of UPS distribution system, and
air distribution systems.
Standby Power Generation: 12,000 KW
UPS Power: 7500 KVA
Telecommunications Data Center
Minneapolis, MN
Designed and managed the expansion of UPS distribution system, and
air distribution systems.
Standby Power Generation: 4000 KW
UPS Power: 750 KVA
Telecommunications Data Center – 6,000 KW
Albuquerque, NM
Designed and managed the expansion of UPS distribution system, and
air distribution systems.
Standby Power Generation: 6000 KW
UPS Power: 3000 KVA
Telecommunications Data Center - 10,000 KW
Orangeburg, NY
Designed and managed the power expansion of the data center.
Designed and managed the installation of 15KV utility distribution,
480V generator systems, N+1 UPS systems and air cooled heat
rejection system .
Standby Power Generation: 10,000 KW
UPS Power: 6250 KVA
Telecommunications Data Center - 2400 KW
Dublin, OH
Designed and managed the power and cooling expansion for the data center.
The project includes standby generator and additional cooling to the space.
The project was designed and constructed in a fully operational data center
without interruption to the data center.
Standby Power Generation: 2400 KW